911333_00(9) Page 8 of 12
Install mechanism case mounting bracket and mechanism case end cap.
6
If necessary, add strike adjusting shim under strike for 3/16” dimension shown.
7
3/16” between center
case cover and strike
Strike
Frame
Center case
cover
Shim
Surface Mount
Metal Door: #25 drill and #10-24 tap inside
Wood Door: 1/8” pilot drill, 1” deep, inside
Sex Bolts
Metal Door: 1/4” drill inside, 13/32” drill outside
Wood Door: 13/32” drill thru
1
Bracket flush against
mechanism case
Device level
on door
Mark mounting
holes and prepare
per chart
2
Slide in
mechanism
case mounting
bracket
Use screws from device mounting screw package
#10-24 pan head sheet metal
for
wood door surface mount
1-1/4”
#10-24 pan head machine
for
sex bolts on 2-1/4” door
1-1/8”
#10-24 pan head machine
for
metal door surface mount or
sex bolts on 1-3/4” door
3/4”
Use screws from end
cap package
#8-18 undercut flat
head machine
1/2”
Install
mounting
screws
Install mechanism
case end cap
34
Vista de pagina 7