Factory-direct-hardware Von Duprin CX9947EO3 Manual de usuario Pagina 1

Busca en linea o descarga Manual de usuario para Para Casa Factory-direct-hardware Von Duprin CX9947EO3. Factory Direct Hardware Von Duprin CX9947EO3 User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 17
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
© 2001 Ingersoll-Rand Co. May be copied for use with specification submittal.
2
Chexit
Controlled Exit Device
Two styles — mechanically
and dimensionally identical,
for a wider selection of
appearance options.
CX98 Series features a
smooth mechanism care.
2
Introduction
Proper selection and application, in addition to safety, are major concerns to all responsible manufacturers.
Chexit Controlled Exit Device is a critical part of an access system, and will provide safe and reliable service
when properly applied and maintained. It is the policy of Von Duprin, Inc., to design and manufacture to a
high standard of quality and reliability in accordance with accepted U.S. domestic and international standards.
UL listed “Controlled Exit Panic Device,” for use on Panic Exit or Fire Exit hardware applications and
tested in accordance to ANSI A156.3, 2001, Grade I. Chexit meets all requirements for NFPA101, Special
Locking Arrangement.
It is intended that the information included in this publication, when properly used, will provide clear and
reliable guidelines to the proper general selection and application. However, the scope of the information
is necessarily limited.
Unusual operating conditions and environments, and other external influence can affect the proper application
of the products represented. Modifications of these products will also affect UL listings. It is recommended
whenever an unusual application condition exists, or when any modification of a product is considered, that
our engineers review the application.
Von Duprin, Inc. application engineering services are available to help ensure proper selection or to review any
areas where users of Von Duprin products may have questions.
Index
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Chexit
Features . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Exit Hardware
Rim Device. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Mortise Lock Device. . . . . . . . . . . . . . . . . . . . . . . 5
Concealed Vertical Rod Device . . . . . . . . . . . . . . . 6
Wood Door Concealed Vertical Rod Device. . . . . . 7
Trims. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9
Strikes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-11
Strike Application/Minimum Stile . . . . . . . . . . . . 10
Accessories
Cylinders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Dummy Push Bar. . . . . . . . . . . . . . . . . . . . . . . . 13
Optional levers . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Cover Plate Kits . . . . . . . . . . . . . . . . . . . . . . . . . 13
Glass Bead Kit . . . . . . . . . . . . . . . . . . . . . . . . . . 13
CD Cylinder Dogging . . . . . . . . . . . . . . . . . . . . . 12
Electric Mortise Lock . . . . . . . . . . . . . . . . . . . . . 12
Electrical Power Transfer. . . . . . . . . . . . . . . . . . . 12
Mini Power Boosters . . . . . . . . . . . . . . . . . . . . . 12
Applications and Wiring. . . . . . . . . . . . . . . . 14-15
Additional Information
Electrical Specifications . . . . . . . . . . . . . . . . . . . 16
Finishes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Fire Label Ratings/Applications. . . . . . . . . . . . . . 16
Handing of Doors . . . . . . . . . . . . . . . . . . . . . . . . 16
How-To-Order . . . . . . . . . . . . . . . . . . . . . . . . . . `17
Nomenclature. . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Typical Specification . . . . . . . . . . . . . . . . . . . . . . 17
CX99 Series features a
grooved mechanism care.
Vista de pagina 0
1 2 3 4 5 6 ... 16 17

Indice de contenidos

Pagina 1 - Controlled Exit Device

© 2001 Ingersoll-Rand Co. May be copied for use with specification submittal.2Chexit™Controlled Exit DeviceTwo styles — mechanically and dimensionally

Pagina 2

Strikes for Rim Devices299 299F 499F 1408Projection 13/16" (21mm) Projection 13/16" (21mm) Projection 13/16" (21mm) One per pair of doo

Pagina 3 - Rim Device

Electric Mortise LockThe electric mortise lock has all the versatility and advantages of thestandard mortise lock, plus being electrically controllabl

Pagina 4 - Mortise Lock Device

13Accessories and OptionsCD Cylinder DoggingCylinder dogging option is available toallow push/pull operation of Chexit, whendisarmed and used in a hea

Pagina 5

14Applications and WiringLegend: + 24 = 24 Volt DC; GND = Ground; SC = Signal Common; FA = Fire Alarm (input); DPS = Door Position Switch; El = Extern

Pagina 6 - Scalp Plate

15Applications and Wiring120 VAC 3 x 14 ga.To Fire Alarm 2 x 18 ga.JunctionBoxEPT-10 EPT-10PS871/873Power SupplyPS871/873Power SupplyCable Cable2 x 12

Pagina 7 - Trim Selection

16Additional InformationFinishesColor US Number BHMA Number A B C D E Brass, Polished US3 605 Brass Plated Brass Buffed Anodized BrassBrass, Satin US4

Pagina 8

1717Additional InformationTypical SpecificationBasic System DesignEach Chexit controlled exit device is an emergency exit system con-sisting of a door

Pagina 9 - Standard Optional

18Chexit™Concealed Vertical Rod DeviceNomenclatureCD — Cylinder DoggingE — Electric Trim ControllCX98 — 98 SeriesCX99 — 99 SeriesNone — Rim Device47 —

Pagina 10 - Strikes for Rim Devices

Chexit™Controlled Exit Device3Request to Exit Switch is built into the device to detect when someone attempts to exit. Applying less than 15 pounds to

Pagina 11 - Accessories and Options

4Chexit™Rim DeviceCX98 and CX99 rim devices for all types of single doors and double doors with mullion, UL listed for accidenthazard installations. C

Pagina 12 - Cylinders

5Chexit™Mortise Lock Device575 575-2576A 576BCX9875 and CX9975 mortise lock devices for all types of single doors or double doors, UL listed for acci

Pagina 13 - Applications and Wiring

Chexit™Concealed Vertical Rod Device6CX9847 and CX9947 concealed vertical rod devices for use on single or double metal doors, UL listed foraccident h

Pagina 14

Chexit™Wood Door Concealed Vertical Rod Device7CX9847WDC and CX9947WDC concealed vertical rod devices for use on single or double wood doors, ULlisted

Pagina 15 - Additional Information

8Trim SelectionTrim operation — rim and vertical rod application, trim will not function when Chexit is armed. Mortise application, trim will function

Pagina 16

9Trim SelectionStandard TrimSeries 990Heavy 10 gage (2.4mm) brass, bronze or stainless steel. DT, NL or TP functionsSeries 991Forged brass 3/4" (

Pagina 17 - Concealed Vertical Rod Device

10Strike Application InformationStrike Application/Minimum Stile Using Standard TrimStandard OptionalSingle door Double door Single door Double doorSt

Comentarios a estos manuales

Sin comentarios