Unscrew and remove the decorative nut cover.
Remove the handle screw (1).
Remove the green high temperature limit stop (2).
Replace it so that the pin goes into the hole for the
desired high temperature.
Reinstall the decorative nut cover (1). Tighten the
handle screw 4 complete turns (2).
Replace the handle (1). Finish tightening the handle
screw (2). Install the screw cover (3).
The temperatures shown in the diagram assume an
incoming hot water temperature of 140
o
F and an
incoming cold water temperature of 50
o
F.